Project Information
Detailed Engineering - Musandam Gas Processing Plant
Description
Client
A leading contracting organization operating in the field of construction and erection for industrial process plants and petrochemical plants.
Engineering Requirement
- Design and Detailed Engineering for 18 Storage Tanks in Musandam Gas Processing Plant
Delivered
- Mechanical design calculations and General Arrangement drawings
- Designed tanks in diameter range of 7M to 51 M and height ranging from 6 M to 22 M
- Detailed drawings for shop fabrication
- Fire Water / Foam Spray / IA line external piping (For only riser pipe & ring pipe)
- Pipe Support Clip Drawings
- API 650, ASME B31.3 codes and standards were followed to ensure high quality of delivery in detailed engineering